BRCM01C (RDC-MD, AC/DC RCM, 12V)
Product Highlights
High compatibility
12V DC interface facilitating compatible integration for EV charger manufacturers in Europe
Flexible integration
Two fault signal pins for solely DC 6mA and Type-A 30mA +DC 6mA alarming
Large apertures
Compact design with 17mm through-hole for charging cable up to 3P+N 32Arsion module is specifically designed, so as to help RDC-MD achieve a high level EMC performance
Improved performance
Fast response time and high level of immunity against nuisance trippingnector with a "hook" structure to fasten the cable connecting to the DC RCM, so as to mitigate the risk of loosend conditions
Cost saving
Cost-effective solution of the built-in residual current device for AC EV charger
BRCM01C (RDC-MD, AC/DC RCM, 12V)
BRCM01C can be seen as either a residual direct current monitoring device (RDC-MD) compliant to IEC 62955 or an AC/DC RCM compliant to IEC 60947-2-(M) and IEC 62955 because the device has separate Pins for solely DC trip output and AC&DC trip output.
With A built-in Mosfet of maximum switching current of 500mA, BRCM01C can be directly coupled to a relay or contactor in EV chargers. In addition to the 12V version, a particular version of 5V products can be provided.
Main Features
- Product Standard: IEC 62955; IEC 60947-2-(M)
- Rated Residual Operating Current (IΔn): 6mA DC / 30mA AC
- Rated Non-operating Residual Current (IΔno): 3mA DC / 15mA AC
- Supply Voltage: 12~24VDC
- Rated current in monitoring circuit: ≤ 32A (1P+N / 3P+N)
- Diameter cable gland of residual current sensor: 17mm (Max. 3P+N 32A)
- Pin 1-6: GND; +12V DC; TEST; DC Trip; AC & DC Trip; NC
- Rated operating temperature: -40~85 ℃
Data Sheet