BRCS03C UL_Main-01
BRCS03C UL_Main-01
BRCS03C UL_Main-02
BRCS03C UL_Main-03
BRCS03C UL_Main-04

›

BRCS/UL

BRCS03C UL

AC/DC Residual Current Sensor (UL Version)

The BRCS03C-U5/BRCS03C-U6 is an AC/DC residual current sensor with two separate fault signal outputs – one Pin conforming to UL2231-2 (CCID20) and the other Pin conforming to IEC 62955 or IEC 62752. It can be used for built-in residual current protection system at AC charging stations.

  • Digital outputs of fault detection conforming to UL2231-2 (CCID20) and IEC 62955 / IEC 62752

  • Cost-effective solution of residual current detection for mode-2/3 EVSE

  • Fast response time facilitating a broad selection of switching devices

  • Accurate measurement and optimization against nuisance tripping

Technical Data

Integration/Wiring Diagrams

Mechanical Outline

Ordering Information

#

Technical Specification

BRCS03C-U5

BRCS03C-U6

101

Poles in monitoring circuit

1P+N / 3P+N

1P+N / 3P+N

102

Rated current in monitoring circuit

32A

32A

103

Rated frequency in monitoring circuit

60Hz

60Hz

104

Rated impulse withstand voltage in monitoring circuit

6kV

6kV

105

Over-voltage category in monitoring circuit

III

III

201

Rated operating voltage in control circuit, Vcc

5VDC±3%

5VDC±3%

202

Power consumption

<500mW

<500mW

203

Pin 1 – N.C.

Not connected

Not connected

204

Pin 2 – Test signal

Digital input

Digital input

205

Pin 3 – Fault signal: X6-IEC62955 (RDC-MD) or X30-IEC62752 (IC-CPD)

Digital output (RDC-MD)

Digital output (IC-CPD)

206

Pin 4 – Fault signal: X20-UL2231 (CCID20)

Digital output

Digital output

207

Pin 5 – GND

GND

GND

208

Pin 6 – Vcc for 5V

+5VDC

+5VDC

301

Rated DC residual operating current IΔdc (IEC 62955)

6mA

6mA

302

Rated DC residual non-operating current IΔndc (IEC 62955)

3mA

3mA

303

Rated AC residual operating current IΔn (UL2231-2)

20mA

20mA

304

Rated AC residual non-operating current IΔnc (UL2231-2)

15mA

15mA

305

Rated AC residual operating current IΔn (IEC 62752)

-

30mA

306

Rated AC residual non-operating current IΔnc (IEC 62752)

-

15mA

307

Electrical endurance

20,000

20,000

308

Rated operating temperature

-40~85 °C

-40~85 °C

309

Pollution degree

2

2

Technical Data

Integration/Wiring Diagrams

Mechanical Outline

Ordering Information

#

Technical Specification

BRCS03C-U5

BRCS03C-U6

101

Poles in monitoring circuit

1P+N / 3P+N

1P+N / 3P+N

102

Rated current in monitoring circuit

32A

32A

103

Rated frequency in monitoring circuit

60Hz

60Hz

104

Rated impulse withstand voltage in monitoring circuit

6kV

6kV

105

Over-voltage category in monitoring circuit

III

III

201

Rated operating voltage in control circuit, Vcc

5VDC±3%

5VDC±3%

202

Power consumption

<500mW

<500mW

203

Pin 1 – N.C.

Not connected

Not connected

204

Pin 2 – Test signal

Digital input

Digital input

205

Pin 3 – Fault signal: X6-IEC62955 (RDC-MD) or X30-IEC62752 (IC-CPD)

Digital output (RDC-MD)

Digital output (IC-CPD)

206

Pin 4 – Fault signal: X20-UL2231 (CCID20)

Digital output

Digital output

207

Pin 5 – GND

GND

GND

208

Pin 6 – Vcc for 5V

+5VDC

+5VDC

301

Rated DC residual operating current IΔdc (IEC 62955)

6mA

6mA

302

Rated DC residual non-operating current IΔndc (IEC 62955)

3mA

3mA

303

Rated AC residual operating current IΔn (UL2231-2)

20mA

20mA

304

Rated AC residual non-operating current IΔnc (UL2231-2)

15mA

15mA

305

Rated AC residual operating current IΔn (IEC 62752)

-

30mA

306

Rated AC residual non-operating current IΔnc (IEC 62752)

-

15mA

307

Electrical endurance

20,000

20,000

308

Rated operating temperature

-40~85 °C

-40~85 °C

309

Pollution degree

2

2